      Source:Corrtest Time:2025-09-10 View:81

      Hydrogen permeation test in steel

      Experimental purpose

      This experiment aims to measuring the atomic hydrogen content in steel and the diffusion rate of them.

      Experiment Setup

      Fig. 1 Hydrogen permeation test setup

      Solution preparation:

      Nickel plating solution(commercial)

      Anode chamber: 0.2mol/L KOH

      Cathode chamber: 0.1mol/L HCl

      Instrument &electrodes:

      Bipotentiostat model CS2350M

      Nickel-plating cell (coating evaluation cell)*1 pcs

      H-cells* 1 set

      Hg/HgO reference electrode 1 pcs

      Q235 carbon steel plate (5cm*5cm*0.1 mm) 1 pcs

      Platinum counter electrode *2 pcs

      Experiment steps

      (1) Specimen pre-processing

      Before the experiment, the carbon steel specimen was polished to a mirror surface with 180#, 400#, 600#, 1000#, and 2000# sandpaper in order, then it was washed with water, wiped with ethanol, and dried in cold air. The specimen was immersed in 0.1 mol/L HCl for 3 min, rinsed with water, and then it was immersed in 0.2 mol/L KOH for 3 min, rinsed with water, dried and placed in a desiccator for use.

      (2) Nickel-plating

      Fig 2 Electrolytic cell and electrode connection for Nickel plating


      As is shown in Figure 2, we used the coating evaluation cell(CS934) to do the nickel-plating. Clamp the carbon steel sheet, add the nickel- plating solution into the cell, then put a small piece of nickel foam into the solution. The red (CE) & yellow alligator (RE) jointly clamp the nickel foam strip, and the green alligator (WE) clampS to the carbon steel(If there is a white sense lead, you should connect together with green WE). Then conduct the “Galvanostatic” test.

      Fig. 3 Parameter setting of Nickel plating

      Set the applied current to be -10 mA/cm2. The exposure area of the specimen was about 7.065cm2, so we applied -70.65 mA. You can set the electrode area in “cell setting”).

      image


      Fig. 4 electrode area modification interface


      The plating process lasted for 30 minutes. After it’s completed, please wash the metal with distilled water, dry in cold air, and then place it in a desiccator for use.


      (2) Hydrogen permeation test

      Fig. 5. Bipotentiostat CS2350M and H-cells


      In anode chamber (left chamber), it’s 3-electrode system: 

      - Working electrode: nickel-plated surface of the carbon steel 

      - Reference electrode: Hg/HgO electrode

      - Counter electrode: platinum electrode


      The hydrogen charging chamber(right chamber) is a 2-electrode system: 

      - the non-nickel-plated surface of carbon steel 

      - the platinum electrode, connecting to yellow (RE) & red(CE) alligators together.


      Firstly, add 250 mL 0.2 mol/L KOH solution to the anode chamber(left), and 250ml 0.1 mol/L HCl to the cathode chamber(right), turn on the bipotentiostat, select “Bipotentiostat”→Hydrogen Diffusion Test.

      image

      Fig. 6. Parameters setting for hydrogen diffusion test


      Set the polarization potential to be 0.45 V, the hydrogen charging peak current to be -22.6 mA (10 mA/cm2), and the hydrogen charging valley current to be 0, recorded the time.

      As the atomic hydrogen [H] in the carbon steel gradually diffused to the surface and was oxidized to be H+, the anodic residual current would gradually be stable. When the residual current was less than 1 mA/ cm2, in the right cell (hydrogen charging)the following reaction would occur:


      Result and analysis

      Hydrogen diffusion coefficient

      Fig. 7. Oxidation current -time curve in hydrogen diffusion test


      From fig. 7 we can obtain Imax=1.0058×10-5 A·cm-2. Find the time t when It / Imax= 0. 63,

      t = 2.380 h = 8568 s.

      The time to start hydrogen charging is 5472 s,so lag time tL=3096 s,thickness of the carbon steel L=0.1cm, according to the formula:

      We can calculate the diffusion coefficient D=5.383×10-7cm2/ s.